Rockwell Automation 1783-Mxxx Stratix 8000 and 8300 Ethernet Managed Switches User Manual User Manual
Page 148
148
Rockwell Automation Publication 1783-UM003I-EN-P - March 2014
Chapter 5 Manage the Switch via the Studio 5000 Environment
3. On the Module Definition dialog box, complete the fields below and click
OK.
Field
Description
Revision
The major and minor revision of the switch:
• Major revision: 1…128
• Minor revision: 1…255
Electronic Keying
Choose one of the following:
• Compatible Module (default)
• Exact Match
• Disable Keying
Connection
Choose one of the following:
• Input Data (default): Enables only an input data connection.
• Data: Enables an input and output data connection.
ATTENTION: This selection enables output tags, which can disable ports and interrupt connections to and through the switch. You can disable a
switch port by setting the corresponding bit in the output tag. The output bits are applied every time the switch receives the output data from
the controller when the controller is in Run mode. When the controller is in Program mode, the output bits are not applied.
The port is enabled if the corresponding output bit is 0. If you enable or disable a port by using the Device Manager Web interface or the CLI, the
port setting can be overridden by the output bits from the controller on the next cyclic update of the I/O connection. The output bits always take
precedence, regardless of whether the Device Manager Web interface or CLI was used to enable or disable the port.
Switch Base
Displays the switch base catalog number for the selected module.
Switch Expansion 1
(14, 18, 22 and 26 port switches only). The catalog number for the copper or fiber expansion modules you are using.
For 14 and 18 port switches, user selection of the expansion module is supported.
For 22 and 26 port switches, Switch Expansion 1 displays 1783-MX08T. User selection of the expansion module is not supported.
Switch Expansion 2
(22 and 26 port switches only). The catalog number for the copper or fiber expansion modules you are using. User selection of the expansion
module is supported.
Data Connection Password
(Data connections only). Enter the password for accessing the switch.