Monitor and Reset the Switch
In the software, you can monitor and reset the switch by accessing the Module
Properties screen.
Field
Description
Identification
Displays the following switch information:
• Vendor
• Product Type
• Product Code
• Revision
• Serial Number
• Product Name
Status
Displays the following status information:
• Major/minor Fault Status
– None
– Recoverable
– Non-recoverable
• Configuration
– Non-default Configuration
– Default Configuration
• Owned
– Yes. There is an I/O connection.
– No. There is not an I/O connection.
• Module Identity
– Match. Agrees with what is specified on the General Tab. In order for the Match condition to exist, the vendor, product
type, product code, and major revision must agree.
– Mismatch. Does not agree with what is specified on the General tab.
The Module Identity field does not take into account the Electronic Keying or Minor Revision selections for the switch that
were specified on the General tab.
Refresh
Click to refresh the tab with new data from the module.
Reset Module
Click to perform a switch reset (power cycle) with the current configuration file. If the Password Confirmation dialog box
appears, enter a password.
IMPORTANT: Resetting a module causes all connections to or through the module to close. This can result in a loss of control.