Rockwell Automation 1771-QA Stepper Positioning Assembly User Manual User Manual
Page 87
4–9
Example Programs
Publication 1771-UM002A–EN–P – May 2000
Preset and Jog Data
Preset and jog data are programmed in a 10-word moveset. The
moveset data is contained in words 310-321 of the file-to-file move
instruction having counter address 0036 as shown in rung 12 (Figure
4.4). The preset and jog data have been logged on the Moveset Data
form (Figure 4.3). The function of the data is summarized in Table
4.A.
Important:
Bits in the moveset control word and single move
control word have been set in hexadecimal notation for
convenience so that move data can be entered in
decimal numbers. The equivalence between
hexadecimal and binary must be known. Otherwise, the
binary data monitor mode would have to be used
separately for setting bit patterns in the control words.
Table 4.A
Functions of Jog/Preset Data (1-Axis Program)
Position
Number
1
Equivalent
Word
2
Word
Description
Function
001
310
Moveset Control word
Bit 10 is set to identify axis 1. (The
hex value of 1 = 0012 in bits 12-10,
respectively.)
002
311
Offset Word
Ignored in this example
003, 004
312, 313
ML, LS Preset Words
Preset of 25
005
314
Single Move Control
Word
Bit 3 is set to identify the moveset as
jog data. Bits 16 & 17 are set to
identify the single move control word.
006
315
Ramp Time
0.5 second to accelerate to final rate
007
316
Final Rate
10 pulses/second or 1000
pulses/second depending on the bit
pattern programmed in rungs 11 and
12.
008
317
Decel Time
0.5 second to decelerate from final
rate to zero.
009, 010
320. 321
Final Position of the jog
999,999 pulses. Allows maximum
travel of the jog move if/as needed.
This could also be programmed as
000,000.
1
Position number of the data monitor display of FFM 0036.
2
Equivalent words in file A of FFM 0036.