beautypg.com

Configuring the adapter as a slave – Rockwell Automation 25-COMM-P PowerFlex PROFIBUS DPV1 Adapter User Manual

Page 36

background image

36

Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013

Chapter 4

Configuring the PROFIBUS Master

Configuring the Adapter as a
Slave

Follow these steps to add and configure a 25-COMM-P adapter as a slave.

1.

Drag the Slave icon into the Bus Configuration window.
The slave is added to the PROFIBUS network and configured to the
Master in a networked relationship.

2.

In the treeview, click ‘+’ to expand the slave you added.

The list in the window above shows the possible input/output
configuration values for a 25-COMM-P Slave. The Datalinks (1...4) allow
the assignment of configured drive parameters to be included in the
PROFIBUS DP I/O data frames that are transferred between the
CompactLogix controller and the PowerFlex 520-series drive.

3.

Click on the 25-COMM-P in the Bus Configuration window.