Setting the node address – Rockwell Automation 25-COMM-P PowerFlex PROFIBUS DPV1 Adapter User Manual
Page 25
![background image](/manuals/578065/25/background.png)
Rockwell Automation Publication 520COM-UM004A-EN-E - November 2013
25
Configuring the Adapter
Chapter 3
Using the PowerFlex 4-Class
HIM to Access Parameters
The PowerFlex 4-class HIM can be used to access parameters in the adapter (see
basic steps shown below). It is recommended that you read through the steps for
your HIM before performing the sequence. For additional HIM information,
refer to the HIM Quick Reference card, publication
To display the
Host parameters, repeat steps 1 through 3 and select
“PowerFlex 525” at step 3.
Setting the Node Address
The value of
Device parameter 05 [Net Addr Cfg] determines the node address if
the adapter’s Node Address switches are set to ‘00’ (Program). When the Node
Address switches are in any other combination of positions, the switches
determine the node address.
1.
Set the value of
Device parameter 05 [Net Addr Cfg] to a unique node
address.
2.
Reset the adapter by power cycling the drive.
Step
Key(s)
Example Display
1.
Power up the drive. Then connect the HIM
to the DSI port of the drive. The Parameters
tab for the drive will be displayed.
2.
Press Sel until the DSEL tab is selected.
3.
Select DSI Device in the DSEL tab if it is not
already selected using the Up Arrow or
Down Arrow.
Press Enter to select DSI Device.
4.
Press the Up Arrow or Down Arrow to scroll
to 25-COMM-P.
Press Enter to reload the HIM to browse
only the communication adapter
(25-COMM-P) parameters.
Parameters
Groups
Linear List
Changed Params
DIAG
PARAM
DSEL
MEM
SEL
Sel
Device Select
DSI Devices
DIAG
PARAM
DSEL
MEM
SEL
and
DSI Devices
PowerFlex 525
25-COMM-P
Sel
DSI Devices
PowerFlex 525
25-COMM-P