I/o assembly instance summary – Rockwell Automation 198 Series C Modular DeviceNet Starter Auxiliary User Manual User Manual
Page 158

A-24 DeviceNet Information
Publication 198-UM002A-EN-P December 2001
I/O Assembly Instance Summary
➊ These assemblies are intended for use when the “Motor Starter Type” attribute in the DeviceNet Interface
object is set to a value greater than zero. This results in the MDSA reporting a Device Type of 22 (Motor
Starter). For a complete description of these I/O assemblies and a complete description of “Motor Starter
Type” operation, refer to Appendix B.
Table A.44
Instance
Type
Size (bytes)
Description
3 ➊
Consumed
1
ODVA Starter Profile output assembly
52 ➊
Produced
1
ODVA Starter Profile input assembly
100
Consumed
(Modules+1) / 2
“Nibble-wise” output assembly
101
Produced
(Modules+5) / 2
“Nibble-wise” input assembly
102
Consumed
I/O modules
Modular “Byte-wise” output assembly for 198-DNG
103
Produced
I/O modules + 2
Modular “Byte-wise” input assembly for 198-DNG
104
Consumed
6
Default “Byte-wise” output assembly for 198-DNG
105
Produced
8
Default “Byte-wise” input assembly for 198-DNG
106
Consumed
16
Default “Byte-wise” output assembly for 198-DN
107
Produced
20
Default “Byte-wise” input assembly for 198-DN
110
Consumed
8
Un-fragmented “Byte-wise” DeviceLogix output
assembly for 198-DNG
111
Consumed
10
Fragmented “Byte-wise” DeviceLogix output assembly
for 198-DNG
112
Consumed
20
“Byte-wise” DeviceLogix output assembly for 198-DN
120
Produced
0…16
Custom Parameter Based input assembly
121
Consumed
0…8
Custom Parameter Based output assembly
150 ➊
Consumed
2
Default Distributed Starter output assembly
151 ➊
Produced
5
Default Distributed Starter input assembly
152 ➊
Consumed
2
Default Reversing Distributed Starter output assembly
153 ➊
Produced
5
Default Reversing Distributed Starter input assembly
154 ➊
Consumed
2
Default Inverter Type Distributed Starter output
assembly
155 ➊
Produced
5
Default Inverter Type Distributed Starter input
assembly
156 ➊
Consumed
2
Default Soft Start Type Distributed Starter output
assembly
157 ➊
Produced
5
Default Soft Start Type Distributed Starter input
assembly
180
Produced
2
Hardware Inputs 1…16
181
Produced
2
Hardware Inputs 17…32
182
Produced
2
Hardware Input Fault Status 1…16
183
Produced
2
Hardware Input Fault Status 17…32
184
Consumed
2
Hardware Outputs 1…16
185
Consumed
2
Hardware Outputs 17…32
186
Consumed
2
Consumed Network Bits 1…16
187
Consumed
2
Consumed Network Bits 17…32
188
Produced
2
Produced Network Bits 1…15
189
Produced
2
DeviceNet Status Bits
190
Produced
2
Module Status Bits 1…16