Additional resources, General precautions, Additional resources general precautions – Rockwell Automation 20C PowerFlex 700H Drives Programming User Manual
Page 8
![background image](/manuals/577164/8/background.png)
8
Rockwell Automation Publication 20C-PM001F-EN-P - March 2012
Preface
Additional Resources
These documents contain additional information concerning related products
from Rockwell Automation.
You can view or download publications at
. To order paper copies of
technical documentation, contact your local Allen-Bradley distributor or
Rockwell Automation sales representative.
General Precautions
7
Resource
Description
Industrial Automation Wiring and Grounding Guidelines,
publicatio
Provides general guidelines for installing a Rockwell
Automation industrial system.
Preventive Maintenance of Industrial Control and Drive
System Equipment, publicat
Provides a checklist that can be used as a guide in
performing preventive maintenance of industrial
control and drive system equipment.
Safety Guidelines for the Application, Installation and
Maintenance of Solid State Control, publication
Provides general guidelines for the application,
installation, and maintenance of solid-state control.
A Global Reference Guide for Reading Schematic Diagrams,
publicatio
wiring diagram symbols used throughout various parts
of the world.
Product Certifications website,
Provides declarations of conformity, certificates, and
other certification details.
ATTENTION: This drive contains ESD (Electrostatic Discharge) sensitive parts and
assemblies. Static control precautions are required when installing, testing,
servicing or repairing this assembly. Component damage may result if ESD
control procedures are not followed. If you are not familiar with static control
procedures, reference A-B publication 8000-4.5.2, “Guarding Against
Electrostatic Damage” or any other applicable ESD protection handbook.
ATTENTION: An incorrectly applied or installed drive can result in component
damage or a reduction in product life. Wiring or application errors, such as,
undersizing the motor, incorrect or inadequate AC supply, or excessive ambient
temperatures may result in malfunction of the system.
ATTENTION: Only qualified personnel familiar with adjustable frequency AC
drives and associated machinery should plan or implement the installation,
start-up and subsequent maintenance of the system. Failure to comply may
result in personal injury and/or equipment damage.
ATTENTION: To avoid an electric shock hazard, verify that the voltage on the bus
capacitors has discharged completely before servicing. Check the DC bus voltage
at the Power Terminal Block by measuring between the +DC and -DC terminals,
between the +DC terminal and the chassis, and between the -DC terminal and
the chassis. The voltage must be zero for all three measurements.
ATTENTION: Risk of injury or equipment damage exists. DPI host products must
not be directly connected together via 1202 cables. Unpredictable behavior can
result if two or more devices are connected in this manner.