Chapter 2
Programming and Parameters
UTILIT
Y
D
iagnos
tics
234
236
[Testpoint 1 Sel]
[Testpoint 2 Sel]
Selects the function whose value is displayed in
[Testpoint x Data]. These are internal values that
are not accessible through parameters.
Note: These parameters were added for future use
in firmware revision 4.001.
Default:
Min/Max:
Units:
499
0/65535
1
235
237
[Testpoint 1 Data]
[Testpoint 2 Data]
The present value of the function
selected in [Testpoint x Sel].
Note: These parameters were added for future use
in firmware revision 4.001.
Default:
Min/Max:
Units:
Read Only
-/+32767
1
Fa
ul
ts
238 [Fault Config 1]
Enables/disables annunciation of the listed faults.
Setting bit 14 “Fan Cooling” to 1 configures the drive for a “Non-Resettable” fault (F32 “Fan
Cooling”). In this case, the drive must be powered-down and the cause of the fault must be
corrected before the fault can be cleared. Setting bit 14 to “0” will configure the drive for a “Non-
Configurable” alarm. In this case the drive will continue to run.
Notes: Bit 9 “Load Loss” should not be changed from “0”. Bit 10 was added for firmware revision
2.001. Bits 2 “Motor Stall” and 11 “Shear PNO Ac” were added for firmware revision 3.001. Bit 14
“Fan Cooling” was added for firmware revision 6.001.
1 = Enabled
0 = Disabled
240 [Fault Clear]
Resets a fault and clears the fault queue.
Default:
Options:
0
0
1
2
“Ready”
“Ready”
“Clear Faults”
“Clr Flt Que”
241 [Fault Clear Mode]
Enables/disables a fault reset (clear faults)
attempt from any source. This does not apply to
fault codes which are cleared indirectly via other
actions.
Default:
Options:
1
0
1
“Enabled”
“Disabled”
“Enabled”
242 [Power Up Marker]
Elapsed hours since initial drive power up. This
value will rollover to 0 after the drive has been
powered on for more than the max value shown.
For relevance to most recent power up see [Fault x
Time].
Default:
Min/Max:
Units:
Read Only
0.0000/429496.7295 Hr
0.1 Hr
244
246
248
250
252
254
256
258
Fil
e
Gr
oup
No
.
Parameter Name & Description
Values
Rela
ted
Name
Re
se
rv
ed
Fa
n C
ooling
Re
se
rv
ed
Re
se
rv
ed
Shear PNO A
c
Ga
te
Dis
ab
le
Lo
ad
Lo
ss
Phase L
oss
Mot
or T
herm
D
ec
el Inhib
Au
tR
st
T
rie
s
Shear P
in
Mot
or Ov
er
ld
Mot
or S
tal
l
UnderV
oltage
Po
w
er
L
os
s
Default
x
1
x
x
0
0
0
1
0
0
0
0
1
1
1
0
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
32