Table 8, “igbt over, For mor, Table 9, “system fault (f10) – Rockwell Automation 20C PowerFlex 700H Drives Programming User Manual
Page 72
72
Rockwell Automation Publication 20C-PM001F-EN-P - March 2012
Chapter 3
Troubleshooting
Table 8 - IGBT Over Temperature Fault (F9) Subcode
Table 9 - System Fault (F10) Subcodes
293
There is a heatsink over temperature in the W phase of power unit 1 (typically frame 12 and 14 drives).
304, 305
There is a heatsink over temperature in power unit 2 (typically frame 12 and 14 drives).
306
There is a heatsink over temperature on the Power board of power unit 2 (typically frame 12 and 14 drives).
307
There is a heatsink over temperature in the U phase of power unit 2 (typically frame 12 and 14 drives).
308
There is a heatsink over temperature in the V phase of power unit 2 (typically frame 12 and 14 drives).
309
There is a heatsink over temperature in the W phase of power unit 2 (typically frame 12 and 14 drives).
530
There is a Thermistor over temperature on the Power board (typically frame 12 and 14 drives).
Subcode
Description
273
The output transistors have exceeded their maximum operating temperature due to an excessive load.
Subcode
Description
Subcode
Description
Action
273
There is an output phase feedback fault from the motor cables.
275
There is an output phase feedback fault from the U phase motor cable (typically frame 11 and 13 drives).
276
There is an output phase feedback fault from the V phase motor cable (typically frame 11 and 13 drives).
277
There is an output phase feedback fault from the W phase motor cable (typically frame 11 and 13 drives).
1042
There is a disturbance at the ASIC fault-input of the Power board - ribbon cable/software.
1058
There is a disturbance at the ASIC fault-input of the Power board in power unit 1 - ribbon cable/software (typically frame 12 and 14 drives).
1074
There is a disturbance at the ASIC fault-input of the Power board in power unit 2 - ribbon cable/software (typically frame 12 and 14 drives).
1090
There is a disturbance at the ASIC fault-input of the Control board - application software.
1298
There is too much disturbance in system bus traffic on the Power board.
1314
There is too much disturbance in system bus traffic on the Power board in power unit 1 (typically frame 12 and 14 drives).
1330
There is too much disturbance in system bus traffic on the Power board in power unit 2 (typically frame 12 and 14 drives).
1553
The charging relay feedback is not working.
1810
The charging relay control is not set on the Power board.
1826
The charging relay control is not set on the Power board on power unit 1 (typically frame 12 and 14 drives).
1827
The charging relay control is not set configured on the Power board on power unit 2 (typically frame 12 and 14 drives).
2065
The Gate Driver board is without auxiliary voltage (Power ASIC-TRIN).
2067
The Gate Driver board for the U phase is without auxiliary voltage (typically frame 11 and 13 drives).
2068
The Gate Driver board for the V phase is without auxiliary voltage (typically frame 11 and 13 drives).
2069
The Gate Driver board for the W phase is without auxiliary voltage (typically frame 11 and 13 drives).
2080
The Gate Driver board in power unit 1 is without auxiliary voltage. (typically frame 11 and 13 drives).
2081
The Gate Driver board in power unit 1 is without auxiliary voltage (typically frame 12 and 14 drives).
2083
The Gate Driver board for the U phase in power unit 1 is without auxiliary voltage (typically frame 14 drives).
2084
The Gate Driver board for the V phase in power unit 1 is without auxiliary voltage (typically frame 14 drives).
2085
The Gate Driver board for the W phase in power unit 1 is without auxiliary voltage (typically frame 14 drives).
2097
The Gate Driver board in power unit 2 is without auxiliary voltage (typically frame 12 and 14 drives).
2099
The Gate Driver board for the U phase in power unit 2 is without auxiliary voltage (typically frame 14 drives).
2100
The Gate Driver board for the V phase in power unit 2 is without auxiliary voltage (typically frame 14 drives).
2101
The Gate Driver board for the W phase in power unit 2 is without auxiliary voltage (typically frame 14 drives).
2370
The TX fiber optic cable connected to H6 on the 700H Control board is broken.
2594
The fiber optic cable connected to TRIP on the Star Coupler board for power unit 1 is broken (typically frame 12 and 14 drives).
2610
The fiber optic cable connected to TRIP on the Star Coupler board for power unit 2 is broken (typically frame 12 and 14 drives).
2834
The fiber optic cable connected to H5 on the ASIC board is broken.
7767
The safe disable inputs on the 20C-DG1 option board have been in a different
state for more than 5 seconds.
• Verify all connections to the 20C-DG01 option board.
• If this fault and subcode occurs again, replace the 20C-DG1 option board.
8023
A thermistor short circuit has been detected on the 20C-DG1 option board.
• Verify the thermistor connections and correct if necessary.
• Verify that the jumper at X10 is in the correct position.
8279
The 20C-DG1 option board has been removed.
Set parameter 359 [20C-DG1 Status] to 1"Remove" and then back to 0 "Ready".
8535
There is an EEPROM error on the 20C-DG1 option board.
Replace the 20C-DG1 option board.
8791
A supply voltage hardware problem has been detected on the 20C-DG1 option
board.
Replace the 20C-DG1 option board.