Utility file – Rockwell Automation 20C PowerFlex 700H Drives Programming User Manual
Page 35
![background image](/manuals/577164/35/background.png)
Rockwell Automation Publication 20C-PM001F-EN-P - March 2012
35
Programming and Parameters
Chapter 2
Utility File
Fil
e
Gr
ou
p
No
.
Parameter Name & Description
Values
Rela
ted
UTILIT
Y
D
ir
ec
tion Co
nfig
190 [Direction Mode]
Selects the method for changing drive direction.
Default:
Options:
0
0
1
2
“Unipolar”
“Unipolar”
“Bipolar”
“Reverse Dis”
320
thru
327
361
thru
366
HIM Ref
Config
192 [Save HIM Ref]
• Bit 0 “Save HIM Ref” enables a feature to save the present frequency reference value issued by
the HIM to Drive memory on power loss. Value is restored to the HIM on power up.
• Bit 1 “ Manual Mode” enables the HIM to control the Speed Reference only or the Speed
Reference, Start and Jog in Manual mode, including two-wire control.
Note: Bit 1 “Manual Mode” was added for firmware revision 4.001.
Save HIM Ref
1 = Enabled
0 = Disabled
Manual Mode
1 = HIM controls Reference, Start, and Jog
0 = HIM controls only the Reference
193 [Man Ref Preload]
Enables/disables a feature to automatically load
the present “Auto” frequency reference value into
the HIM when “Manual” is selected. Allows
smooth speed transition from “Auto” to “Manual.”
Default:
Options:
0
0
1
“Disabled”
“Disabled”
“Enabled”
MOP
Co
nfi
g
194 [Save MOP Ref]
Enables/disables the feature that saves the present MOP frequency reference at power down or
at stop.
1 = Save at power down
0 = Do not save
195 [MOP Rate]
Sets rate of change of the MOP reference in
response to a digital input.
Default:
Min/Max:
Units:
1.0 Hz/s
30.0 RPM/s
0.2/[Maximum Speed]
6.0/[Maximum Speed]
0.1 Hz/s
0.1 RPM/s
Driv
e Memo
ry
196 [Param Access Lvl]
Selects the parameter display level viewable on
the HIM.
Basic = Reduced parameter set
Advanced = Full parameter set
Default:
Options:
0
0
1
2
“Basic”
“Basic”
“Advanced”
“Reserved”
Mode
Direction Change
Unipolar
Drive Logic
Bipolar
Sign of Reference
Reverse Dis
Not Changeable
Name
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Manua
l Mode
Sa
ve
HIM
Re
f
Default
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0
1
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Name
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
At
S
to
p
At
P
owr
D
own
Default
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0
0
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
32