Capture + tolerances – NTi Audio XL2 Sound Level Meter User Manual
Page 153

153
Capture + Tolerances
Store your individual tolerance file as txt-file in the XL2 folder
•
“Tolerances”.
Start the XL2 tolerance mode and load the new tolerance file
•
from the SD Card.
All entries in the customized tolerance file
•
need to be tab-separated.
The individual tolerance file entries may be in
•
any order; no sequential order required.
Tolerance file templates and standardized tol-
•
erance files are a free download for all regis-
tered XL2 customers on the support website
at http://my.nti-audio.com. For details see the
chapter My NTi Audio in this manual.
#Unit
dBr
#Mode
HighLow
#Columns
Frequency
Min
Ideal
Max
#ATolerances
UNDEF
80
undef
90
#ZTolerances
UNDEF
80
undef
90
#BandTolerances
20
70
undef
80
1000
70
undef
80
1000
73
undef
77
4000
73
undef
77
4000
70
undef
80
20000
70
undef
80
#LevelOffset
0
#HideUnusedBands
false
#nAllowedViolations
0