beautypg.com

Architectural, Rake detail – Metal Sales Soffit Panel User Manual

Page 42

background image

© Metal Sales Manufacturing Corporation / Subject to change without notice, effective 02/09.

41

ARCHITECTURAL

RAKE DETAIL

(Direct Fasten)
(Optional)

INSTALLATION NOTES

Z-Closure

Double Bead Tape Sealant

Cleat

Roof Panel

Moisture Barrier (by others)

Rake

Pancake Head Woodscrew (1'-0" o.c.)

Pop-Rivet (1'-0" o.c.)

Double Bead Tape Sealant

Pancake Head Woodscrew (1'-0" o.c.)

1. If panel ends off module bend flat part of the panel up a minimum of 1", otherwise skip to the next note.
2. Apply a row of Double Bead Tape Sealant to the flat part of the panel next to the panel rib or vertical field bent leg.
3. Position Z-Closure over tape sealant and fasten to wood substrate with #10-12 x 1" Pancake Head Woodscrew, 12" o.c.

Fastener must penetrate through the Z-Closure, Tape Sealant, and panel.
4. Position and install Cleat to wall with appropriate fastener, 12” o.c. Make sure Cleat installation allows for proper Rake

attachment.
5. Apply a row of Double Bead Tape Sealant to top leg of the Z-Closure.
6. Install Rake by sliding the open hem onto the Cleat and then attaching to the Z-Closure with

1

/

8

"x

3

/

16

" Pop Rivets at 12" o.c.

7. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a
bead of Tube Sealant between the flashings and securing with pop rivets 2.5" o.c.

(Not available for Pro-Loc.)

3:12 Slope

Minimum