Architectural, Extended eave detail – Metal Sales Soffit Panel User Manual
Page 39

© Metal Sales Manufacturing Corporation / Subject to change without notice, effective 02/09.
38
ARCHITECTURAL
EXTENDED EAVE DETAIL
INSTALLATION NOTES
Pancake Head Woodscrew (1'-0" o.c.)
Tube Sealant
Double Bead Tape Sealant
Cleat
Roof Panel
Moisture Barrier (by others)
Extended Eave
Pancake Head Woodscrew (1'-0" o.c.)
Clip
All Eave flashings must be installed prior to panel installation.
1. Position and install Cleat to wall with appropriate fastener, 12" o.c. Make sure Cleat allows for proper Extended Eave
attachment.
2. Install Extended Eave flashing by sliding open hem onto Cleat and resting Extended Eave Flashing back against substrate.
Fasten to substrate with #10-12 x 1" Pancake Head Woodscrew, 12"o.c.
3. Apply a row of Double Bead Tape Sealant to extended leg of the Extended Eave flashing.
4. Install panel by engaging field hemmed end of panel (see pages 59 and 60) to Extended Eave (see pages 24-34 for panel
installation).
5. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a
bead of Tube Sealant between the flashings and securing with pop rivets 2.5" o.c.
Panel rib must be field
notched and flat part
of panel must be field
bent to accept extended
eave (see pages 59 and
60).
3:12 Slope
Minimum