Architectural, Design / installation considerations – Metal Sales Soffit Panel User Manual
Page 24

© Metal Sales Manufacturing Corporation / Subject to change without notice, effective 02/09.
23
ARCHITECTURAL
DESIGN / INSTALLATION CONSIDERATIONS
1 FASTENER
1 FASTENER
1 FASTENER
#10-12 x 1" PANCAKE WOODSCREW
#10-12 x 1" PANCAKE WOODSCREW
#10-12 x 1" PANCAKE WOODSCREW
1 FASTENER
NUMBER
REQUIRED
TYPE OF FASTENER
APPLICATION
INSTALLATION
REQUIREMENTS
24 GAUGE
24 GAUGE
CLIP
SPACING
1'-6" O.C.
1'-6" O.C.
1'-6" O.C.
#10-12 x 1" PANCAKE WOODSCREW
22 GAUGE
1'-6" O.C.
CLIPS OVER
5
/
8
" WOOD DECK
CONST. #393
CLIPS OVER
5
/
8
" WOOD DECK
CONST. #394
UL-90
UL-90
UL-90
UL-90
22 GAUGE
PANEL TYPE
PRO-LOC I
PRO-LOC II
24 GAUGE
2'-0" O.C.
22 GAUGE
2'-0" O.C.
UL-90
UL-90
CLIPS OVER
5
/
8
" WOOD DECK
CONST. #430
1 FASTENER
#10-12 x 1" PANCAKE WOODSCREW
1 FASTENER
#10-12 x 1" PANCAKE WOODSCREW
CLIP OVER RIGID
INSULATION /
METAL DECK
CONST. #397A
CLIPS OVER
5
/
8
" WOOD DECK
CONST. #398
24 GAUGE
1'-6" O.C.
22 GAUGE
1'-6" O.C.
UL-90
UL-90
24 GAUGE
2'-0" O.C.
2'-0" O.C.
UL-90
UL-90
22 GAUGE
1 FASTENER
1 FASTENER
*#14-13 x L DEKFAST SCREWS
*#14-13 x L DEKFAST SCREWS
1 FASTENER
#10-12 x 1" PANCAKE WOODSCREW
1 FASTENER
#10-12 x 1" PANCAKE WOODSCREW
CLIP OVER RIGID
INSULATION /
METAL DECK
CONST. #398A
24 GAUGE
1'-6" O.C.
1'-6" O.C.
UL-90
UL-90
22 GAUGE
1 FASTENER
1 FASTENER
*#14-13 x L DEKFAST SCREWS
*#14-13 x L DEKFAST SCREWS
MINI-BATTEN
1
MAXI-BATTEN
The following chart highlights UL 580 Class 90 for clip installation on the selected applications. (See Fastener Selection
*XLGH SDJH IRU RWKHU IDVWHQHUV DYDLODEOH )RU PRUH LQIRUPDWLRQ RQ 8/ &RQVWUXFWLRQ QXPEHUV UHIHU WR 8/ 5RR¿QJ 0DWH-
rials and System Directories. Panel gauges and clip spacing should be determined by a professional engineer according to the
governing building code.
* Length of Dekfast will vary depending on the total thickness of the rigid insulation and metal decking. (See page 20.)
** Contact your local Metal Sales branch representative for more information. (See pages 2 and 3.)
1. For 1" Mini-Batten over
5
/
8
" plywood deck only.
2. Subject to project loading, closer fastener spacing may be required.
BEARING PLATE
PANEL APPLICATIONS
IMAGE II
2
**CALL YOUR METAL SALES
BRANCH FOR
ASTM-E1592 UPLIFT VALUES
OVER
5
/
8
" PLYWOOD DECK
AND METAL DECK
26 GAUGE
1'-0" O.C.
Standard
26 GAUGE
1'-6" O.C.
Standard
26 GAUGE
# REQ.
TYPE OF FASTENER
APPLICATION
INSTALLATION
REQUIREMENTS
FASTENER
SPACING
PANEL TYPE
MAX UPLIFT
PRESSURE
2'-0" O.C.
Standard
46 psf
39 psf
32 psf