What is the ApplicationTemplate PackML?
Elements of the ApplicationTemplate PackML
20
Lenze · ApplicationTemplate PackML · 1.0 EN - 05/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.3.6.1
Predefined operating modes in ModApp1
Each machine module contains the predefined operating modes Producing, Maintenance and
Manual.
The operating modes are located in the machine module template in the folder
A66_EmptyModule_PackML ModApp1\Modes.
• The module application App1 contains the instances of the mode blocks Producing,
Maintenance and Manual.
• The mode block instances are called in the modes method.
Where can the operating modes be defined?
The configuration of the operating modes is defined in the
A12_PackMLConfiguration folder.
There, it is defined, for instance, which state is active and in which states a changeover of the mode
is permissible.
The mode FBs are declared in the MAP-FB in the \ModApp1 folder.
Call of the mode FBs in the respective modes method