C13855 | com word from standard device, C13860 | settings, C13861 | bus status – Lenze E94AYCPM User Manual
Page 95: C13862 | bus counter, C13861, 14 parameter reference
Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17
95
14
Parameter reference
14.2
Parameters of the communication module for slot MXI1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13855
C13860
C13861
C13862
Parameter | Name:
C13855 | COM word from standard device
Data type: BITFIELD_32
Index: 10720
d
= 29E0
h
Available from software version 01.21!
This code is for device-internal use only and must not be overwritten by the user!
Parameter | Name:
C13860 | Settings
Data type: UNSIGNED_8
Index: 10715
d
= 29DB
h
Display of the current configuration data.
Display area
(min. value | unit | max. value)
0
255
Subcodes
Info
C13860/1
PROFIsafe
• 0: Not active
• 1: Active
C13860/2
Number of process data words (1 ... 32 words)
C13860/3
DRIVECOM parameter data channel
• 0: Not active
• 1: Active
C13860/4
Number of PROFIsafe words (0 or 4 words)
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13861 | Bus status
Data type: UNSIGNED_16
Index: 10714
d
= 29DA
h
Bit-coded display of the current bus state.
Querying the current bus status ( 84)
Display area
(min. value | unit | max. value)
0
65535
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13862 | Bus counter
Data type: UNSIGNED_16
Index: 10713
d
= 29D9
h
When the maximum count value of 65535 is reached, the counter starts again with 0.
Display area
(min. value | unit | max. value)
0
65535
Subcodes
Info
C13862/1
Data cycles per second
C13862/2
Total data cycles
C13862/3
Total parameterisation events
C13862/4
Total configuration events
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT