Parameter data transfer

9.3

PROFIdrive parameter data channel (DP-V1)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Parameter format

Parameter value

Byte 11

Byte 12

Format

Number of values

Field

Data type

Values

Format

U8

0x02: Integer8

0x03: Integer16

0x04: Integer32

0x05: Unsigned8

0x06: Unsigned16

0x07: Unsigned32

0x09: Visible string

0x0A: Octet string

0x40: Zero

0x41: Byte

0x42: Word

0x43: Double word

Number of values

U8

0x01 or number of written subindices/parameters (with

several subindices/parameters only the parameter value

is repeated).

In the case of string codes, the number of characters is

entered here.

Byte 13

Byte 14

Byte 15

Byte 16

Value

Field

Data type

Values

Value

String

Any (length > 4 bytes possible)

U8

0x00 .... 0xFF

U16

0x0000 .... 0xFFFF

U32