C13851 | all words from master, C13852 | all words to standard device, C13853 | all words from standard device – Lenze E94AYCPM User Manual
Page 94: C13854 | com word to standard device, 14 parameter reference
14
Parameter reference
14.2
Parameters of the communication module for slot MXI1
94
Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13851
C13852
C13853
C13854
Parameter | Name:
C13851 | All words from master
Data type: UNSIGNED_16
Index: 10724
d
= 29E4
h
Display of the process data words transferred from the PROFIBUS master to the communication module.
In the subcodes 1 ... 32, all process data words to the master are displayed. Only the configured process data words
are valid.
Display area
(min. value | unit | max. value)
0
65535
Subcodes
Info
C13851/1
...
C13851/32
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13852 | All words to standard device
Data type: UNSIGNED_16
Index: 10723
d
= 29E3
h
Display of the process data words 1 ... 32 transferred from the communication module to the standard device.
In the subcodes 1 ... 32, all process data words from the communication module are displayed.
Display area
(min. value | unit | max. value)
0
65535
Subcodes
Info
C13852/1
...
C13852/32
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13853 | All words from standard device
Data type: UNSIGNED_16
Index: 10722
d
= 29E2
h
Display of the process data words 1 ... 32 transferred from the standard device to the communication module.
In the subcodes 1 ... 32, all process data words from the standard device are displayed.
Display area
(min. value | unit | max. value)
0
65535
Subcodes
Info
C13853/1
...
C13853/32
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13854 | COM word to standard device
Data type: BITFIELD_32
Index: 10721
d
= 29E1
h
Available from software version 01.21!
This code is for device-internal use only and must not be overwritten by the user!