2
Safety instructions
2.2
Device- and application-specific safety instructions
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2.2
Device- and application-specific safety instructions
• During operation, the communication module must be firmly connected to the standard device.
• With external voltage supply, always use a separate power supply unit, safely separated to EN
61800-5-1 in every control cabinet (SELV / PELV).
• Only use cables corresponding to the given specifications.
2.3
Residual hazards
Protection of persons
If the Servo Drives 9400 are operated on a phase earthed mains with a rated mains voltage ≥ 400 V,
external measures need to be implemented in order to ensure protection against accidental
contact.
Device protection
The communication module contains electronic components which may be damaged or destroyed
by electrostatic discharge.
Documentation for the standard device, control system, plant/machine
All other measures prescribed in this documentation must also be implemented.
Observe the safety instructions and application notes specified in the documentation.