C13897 | profisafe: target address, C13899 | station address, C13900 | firmware product type – Lenze E94AYCPM User Manual
Page 100: C13901 | firmware compilation date, C13902 | firmware version, C13899, Becom, 14 parameter reference

14
Parameter reference
14.2
Parameters of the communication module for slot MXI1
100
Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13897
C13899
C13900
C13901
C13902
Parameter | Name:
C13897 | PROFIsafe: Target address
Data type: UNSIGNED_16
Index: 10678
d
= 29B6
h
Setting of the PROFIsafe target address
• Only required if the SM301 (E94AYAE) safety module is used.
• A unique PROFIsafe target address must be assigned to each controller.
Setting range
(min. value | unit | max. value)
Lenze setting
1
65534 1
;
Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX ; COM MOT
Parameter | Name:
C13899 | Station address
Data type: UNSIGNED_8
Index: 10676
d
= 29B4
h
Optional setting of the station address (instead of setting via DIP switches 1 ... 64)
• The station address set here only becomes effective if the DIP switches 1 ... 64 have been set to OFF prior to mains
switching.
• The active station address is displayed under
Note: A change of the station address will not be effective until the " Save parameter set" device command has been
executed and another mains switching for the communication module/controller has been performed.
Setting the station address ( 31)
Setting range
(min. value | unit | max. value)
Lenze setting
3
126 3
;
Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX ; COM MOT
Parameter | Name:
C13900 | Firmware product type
Data type: VISIBLE_STRING
Index: 10675
d
= 29B3
h
Display of the product type (string with a length of 8 bytes)
The following identification code is displayed: "E94AFCPM".
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13901 | Firmware compilation date
Data type: VISIBLE_STRING
Index: 10674
d
= 29B2
h
Display of the compilation date of the firmware (string with a length of 20 bytes)
The date ("MMM DD YYYY") and time ("hh:mm:ss") are displayed, e.g. "Mar 21 2005 12:31:21".
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13902 | Firmware version
Data type: VISIBLE_STRING
Index: 10673
d
= 29B1
h
Display of the firmware version (string with a length of 5 bytes)
Example: "01.21"
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT