C14855 | com word from standard device, C14860 | settings, C14861 | bus status – Lenze E94AYCPM User Manual
Page 104: C14862 | bus counter, C14861, Indica, 14 parameter reference
14
Parameter reference
14.3
Parameters of the communication module for slot MXI2
104
Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14855
C14860
C14861
C14862
Parameter | Name:
C14855 | COM word from standard device
Data type: BITFIELD_32
Index: 9720
d
= 25F8
h
Available from software version 01.21!
This code is for device-internal use only and must not be overwritten by the user!
Parameter | Name:
C14860 | Settings
Data type: UNSIGNED_8
Index: 9715
d
= 25F3
h
Display of the current configuration data.
Display area
(min. value | unit | max. value)
0
255
Subcodes
Info
C14860/1
PROFIsafe
• 0: Not active
• 1: Active
C14860/2
Number of process data words (1 ... 32 words)
C14860/3
DRIVECOM parameter data channel
• 0: Not active
• 1: Active
C14860/4
Number of PROFIsafe words (0 or 4 words)
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14861 | Bus status
Data type: UNSIGNED_16
Index: 9714
d
= 25F2
h
Bit-coded display of the current bus state.
Querying the current bus status ( 84)
Display area
(min. value | unit | max. value)
0
65535
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14862 | Bus counter
Data type: UNSIGNED_16
Index: 9713
d
= 25F1
h
When the maximum count value of 65535 is reached, the counter starts again with 0.
Display area
(min. value | unit | max. value)
0
65535
Subcodes
Info
C14862/1
Data cycles per second
C14862/2
Total data cycles
C14862/3
Total parameterisation events
C14862/4
Total configuration events
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT