beautypg.com

2 establishing emf2133ib compatibility, Establishing emf2133ib compatibility, 6commissioning – Lenze E94AYCPM User Manual

Page 32

background image

6

Commissioning

6.3

Possible DIP switch settings

32

Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Setting the station address via the »Engineer«
In the »Engineer«, the station address can be set via the Settings tab.

Invalid addresses are displayed in red in the Station address input field (code

C13899

/

C14899

).

Save the changed settings via the device command C00002 = 11 (save start parameters).

6.3.2

Establishing EMF2133IB compatibility

Establishing EMF2133IB compatibility is necessary if you need to communicate with systems using

an EMF2133IB PROFIBUS communication module.
Software compatibility can be set via DIP switch 2133.

Switch

Switch position

Function

2133

ON

Establishing EMF2133IB compatibility

OFF

No EMF2133IB compatibility

Note!

• In the compatibility mode "EMF2133IB", only the DRIVECOM parameter data channel

(DP-V0) and the Lenze device control can be used.

• Switch off the voltage supply of the communication module and then on again in

order to activate changed settings.

Communication manual for the EMF2133IB module
Here you can find information on the configuration of the EMF2133IB communication

module and the identification of the module on the bus.