14 parameter reference, 4 table of attributes 112, Table of attributes – Lenze E94AYCPM User Manual
Page 112
![background image](/manuals/565754/112/background.png)
14
Parameter reference
14.4
Table of attributes
112
Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Table of attributes
Code
Name
Index
Data
Access
dec
hex
DS
DA
DT
Factor
R
W
CINH
All words to master
10725
29E5
A
32
UNSIGNED_16
1
;
All words from master
10724
29E4
A
32
UNSIGNED_16
1
;
All words to standard device
10723
29E3
A
32
UNSIGNED_16
1
;
All words from standard device
10722
29E2
A
32
UNSIGNED_16
1
;
Settings
10715
29DB
A
4
UNSIGNED_8
1
;
Bus status
10714
29DA
E
1
UNSIGNED_16
1
;
Bus counter
10713
29D9
A
4
UNSIGNED_16
1
;
Baud rate
10712
29D8
E
1
UNSIGNED_8
1
;
Active station address
10711
29D7
E
1
UNSIGNED_8
1
;
Display: Most recent PRM data
10710
29D6
E
1
OCTET_STRING
;
Display: Most recent CFG data
10709
29D5
E
1
OCTET_STRING
;
Display: Most recent diagnostic data
10708
29D4
E
1
OCTET_STRING
;
Display: DP state
10707
29D3
E
1
UNSIGNED_8
1
;
Reaction on communication fault
10695
29C7
A
2
UNSIGNED_8
1
;
;
Monitoring time: Data exchange
10694
29C6
E
1
UNSIGNED_16
1
;
;
Monitoring time: Watchdog
10693
29C5
A
2
UNSIGNED_32
1
;
Clear process data
10690
29C2
E
1
UNSIGNED_8
1
;
;
Set ext. diagnostic bit upon
10689
29C1
E
1
BITFIELD_8
;
;
Suppress signalling diag. mess. upon
10688
29C0
E
1
BITFIELD_8
;
;
PROFIsafe: Target address
10678
29B6
E
1
UNSIGNED_16
1
;
;
Station address
10676
29B4
E
1
UNSIGNED_8
1
;
;
Firmware product type
10675
29B3
E
1
VISIBLE_STRING
;
Firmware compilation date
10674
29B2
E
1
VISIBLE_STRING
;
Firmware version
10673
29B1
E
1
VISIBLE_STRING
;
Display: DIP switch setting
10655
299F
E
1
UNSIGNED_8
1
;
All words to master
9725
25FD
A
32
UNSIGNED_16
1
;
All words from master
9724
25FC
A
32
UNSIGNED_16
1
;
All words to standard device
9723
25FB
A
32
UNSIGNED_16
1
;
All words from standard device
9722
25FA
A
32
UNSIGNED_16
1
;
Settings
9715
25F3
A
4
UNSIGNED_8
1
;
Bus status
9714
25F2
E
1
UNSIGNED_16
1
;
Bus counter
9713
25F1
A
4
UNSIGNED_16
1
;
Baud rate
9712
25F0
E
1
UNSIGNED_8
1
;
Active station address
9711
25EF
E
1
UNSIGNED_8
1
;
Display: Most recent PRM data
9710
25EE
E
1
OCTET_STRING
;
Display: Most recent CFG data
9709
25ED
E
1
OCTET_STRING
;
Display: Most recent diagnostic data
9708
25EC
E
1
OCTET_STRING
;
Display: DP state
9707
25EB
E
1
UNSIGNED_8
1
;
Reaction on communication fault
9695
25DF
A
2
UNSIGNED_8
1
;
;
Monitoring time: Data exchange
9694
25DE
E
1
UNSIGNED_16
1
;
;
Monitoring time: Watchdog
9693
25DD
A
2
UNSIGNED_32
1
;
Clear process data
9690
25DA
E
1
UNSIGNED_8
1
;
;
Set ext. diagnostic bit upon
9689
25D9
E
1
BITFIELD_8
;
;
Suppress signalling diag. mess. upon
9688
25D8
E
1
BITFIELD_8
;
;
PROFIsafe: Target address
9678
25CE
E
1
UNSIGNED_16
1
;
;
Station address
9676
25CC
E
1
UNSIGNED_8
1
;
;
Firmware product type
9675
25CB
E
1
VISIBLE_STRING
;
Firmware compilation date
9674
25CA
E
1
VISIBLE_STRING
;