beautypg.com

13 error messages, 1 short overview of the profibus error messages, Error messages – Lenze E94AYCPM User Manual

Page 87

background image

Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17

87

13

Error messages

13.1

Short overview of the PROFIBUS error messages

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13

Error messages

This chapter supplements the error list for the Servo Drive 9400 contained in the software manual

and in the »Engineer« online help with the error messages of the communication module.

13.1

Short overview of the PROFIBUS error messages

The following table lists all PROFIBUS error messages in numerical order of the error number.

Furthermore the preset error response and – if available – the parameters for setting the error

response are specified.

Tip!
When you click the cross-reference in the first column, you will see a detailed description

(causes and remedies) of this error message.

Software manual/online help for Servo Drive 9400
Here you can find general information on diagnostics & fault analysis and on error

messages.

Error number

Designation

Response (Lenze setting)

Adjustable in

hex

dec

0x00c83100

13119744

Profibus: Lost connection to 9400 base device

0: No response

-

0x00c85531

13129009

Profibus: No memory access

6: Information

-

0x00c85532

13129010

Profibus: Read memory error

6: Information

-

0x00c85533

13129011

Profibus: Write memory error

6: Information

-

0x00c86010

13131792

Profibus: Restart after watchdogreset

1: Fault

-

0x00c86011

13131793

Profibus: Internal error

1: Fault

-

0x00c86100

13132032

Profibus: Internal error

0: No response

-

0x00c86101

13132033

Profibus: Internal error

1: Fault

-

0x00c86110

13132048

Profibus: Internal mapping error

4: Warning locked

-

0x00c8641f

13132831

Profibus: Invalid parameter record

1: Fault

-

0x00c86420

13132832

Profibus: Error: Lenze setting loaded

1: Fault

-

0x00c88130

13140272

Profibus watchdog: Monitoring time elapsed

0: No response

C13880/1

C14880/1

0x00c88131

13140273

Profibus: Data_Exchange state exited

0: No response

C13880/1

C14880/1

0x00c88132

13140274

Profibus watchdog: DP-V1 MSAC2 elapsed

0: No response

C13880/2

C14880/2