5 telegram examples, 1 read request: querying the heatsink temperature, Telegram examples – Lenze E94AYCPM User Manual
Page 72: Read request: querying the heatsink temperature, 9parameter data transfer
9
Parameter data transfer
9.3
PROFIdrive parameter data channel (DP-V1)
72
Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.3.5
Telegram examples
9.3.5.1
Read request: Querying the heatsink temperature
The heatsink temperature of the controller is to be read.
• Code to be read: C00061
• Heatsink temperature: 43 °C
Parameter request
Parameter response to a correctly executed read request
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Request identification
Axis
Number of indices
0xXX
0x01
0x00
0x01
Request parameters for reading
Byte 5
Byte 6
Attribute
Number of subindices
0x10
0x00
Value
No subindex
Byte 7
Byte 8
Byte 9
Byte 10
Index
Subindex
High byte
Low byte
High byte
Low byte
0x5F
0xC2
0x00
0x00
Index = 24575 - code no. = 24575 - 61 = 24514 = 0x5F C2
No subindex
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
(mirrored)
Response identification
Axis
(mirrored)
Number of indices
0xXX
0x01
0x00
0x01
Parameter has been read
Byte 5
Byte 6
Format
Number of values
0x03
0x01
Integer16
1 value
Byte 7
Byte 8
Value
High byte
Low byte
0x00
0x2B
Value read = 0x 00 2B = 43 x 1 (internal factor) = 43 [°C]