EMS mains connection concepts
Half wave (coded)
l
35
EDS84DPS424 EN 5.0
3.7
EMS mains connection concepts
The mains connection concepts can also be realised with 8400 protec EMS, e.g.
ƒ
Loop−through technique from device to device for multi−axis applications
Moreover, 8400 protec EMS controllers support the following (depending on the device
version):
ƒ
Contact conductor connection for mains, control bar and message bar (half wave
and coded half wave)
ƒ
Control signals via mains voltage (power wave)
ƒ
Control signals via rail bus
ƒ
Inductive transmission of energy and signals
For establishing a drive system, more adjusted components are required.
3.7.1
Half wave (coded)
X10
X1
3/PE AC
3/PE AC
~
=
~
=
X10
3/PE AC
~
=
E84D ...
G
E84D
.../
EP
E84D
.../
EM
L1
L2
L3
PE
MS
SS
SS/MS
SS/MS
X11
4
CAN
E84D
...
LP
E84D
...
LM
6
6
E84DVK004_A
L1 ... L3, PE
Sliding bar conductors for mains and PE conductor
SS
Control bar SS1, SS2
ms
Message bar MS1
8400 protec EMS controller for single−axis drive
8400 protec EMS controller for multi−axis drive
X10
Mains
X11
Mains loop−through technique
CAN
CANopen communication
Controller, e.g. 8400 motec, as auxiliary drive
X1
Mains (with accessory plug−in module E84DZEVB...: X10)