5

System architecture

5.3

Direct connection

52

Lenze · Controller-based Automation · System Manual · DMS 1.4 EN · 04/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.3.2

Device series 8400/9400: Which Engineering tool do I need?

»EASY Starter« / »Engineer«

For a direct connection to the 8400/9400

device series, the Engineering PC requires

fieldbus-specific adapters.
Example: A diagnostic adapter for direct

connection of the Engineering PC to an inverter

with diagnostics interface.

Note!

• As soon as the controller has been commissioned, a direct connection should no

longer be used since, depending on the bus system, the real-time capacity of the bus

system may be disturbed.

• When the CANopen bus system is used, a direct connection may cause

communication faults.