3 "visu" runtime software, Visu" runtime software, 4system components – Lenze Controller-based Automation User Manual
Page 34

4
System components
4.4
Runtime software of the Lenze Controllers
34
Lenze · Controller-based Automation · System Manual · DMS 1.4 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.4.3
"Visu" runtime software
The "Controller-based Automation" system enables the central visualisation of the automation
system.
The visualisation can either run on a separate Controller or monitor panel or on the Controller on
which the "Logic" or "Motion" runtime software is running.
Various options described in the following sections are available for the communication link.
Functionality
The "Visu" mode ...
• extends the Controller to a visualisation device;
• can be used separately or in addition to "Logic" or "Motion".
Engineering tool required: »VisiWinNET«
Note!
There is no OPC server available for PROFIBUS and PROFINET.
Controller c300/p300:
• The OPC communication for »VisiWinNET« is exclusively available for Controller p300
without PLC.
• Otherwise, only the Lenze "Logic&Motion" direct driver can be used for the data
exchange between »VisiWinNET« and PLC.