beautypg.com

3 electrical installation – Festo DHTG User Manual

Page 27

background image

DHTG

Festo – DHTG – 1404d English

27

5.3

Electrical installation

If proximity switches are used for position sensing:

Note

Faulty switching or damage to the proximity

switches due to being screwed in too far.

Make sure the proximity switches are

screwed into the thread (U), (V) or (W) up to

the following maximum depth.

Max. screw-in depth

Size

65

90

140

220

Thread (U), (W)

[mm]

11.5

11.5

13.5

18.5

Thread (V)

[mm]

19.7

14

16

21

Tab. 8

Screw the proximity switches into the following threaded holes:

Sensing

Direction of rotation of plate

Clockwise rotation

Anti-clockwise rotation

(reciprocating operation/

flexible control)

Direction of rotation

(W)

(U)

Locking mechanism

(V)

(V)

Piston end position

(U)

(W)

Tab. 9

When the DHTG is used with 3-part split (DHTG-140 and DHTG-220):

Note

Based on the design, the rotating plate can engage in an intermediate position

(corresponding to the 6-index stations).

After an emergency stop / overload, make sure that the rotating plate is in the

desired position before the system is placed back in operation.

If the rotating plate is engaged in an intermediate position, bring the locked

rotating plate into the desired position by jerking and twisting it against the

overload protection.

Fig. 8

(U)

(V)

(W)