beautypg.com

1 additional connection examples, Additional connection examples, Asimon – EUCHNER Safety Basic Monitor User Manual

Page 21: Asi – + – aux, Safety basic monitor product description, S52 s61, 10ma

background image

Subject to reasonable modifications due to technical advances

Id.-No.: 114013

Issue date: 14.11.2011

EUCHNER GmbH + Co. KG

21

Kohlhammerstraße 16, D-70771 Leinfelden-Echterdingen

Tel. +49/711/7597-0, Fax +49/711/753316

Safety Basic Monitor

Product Description

4.13.1

Additional connection examples

safety input

standard inputs

message outputs

contactor

Tab. 4-6. Additional connection examples

1.14

ext. out

ASI

+

0

V

ext. out

ASI

2.14

ext. out

AUX+

ext. in

0

V

ext. out

AUX–

ext. in

S

71 S

72 S

81 S

82

S

42 S

41 S

32 S

31

S

62 S

61 S

52 S

51

S

22 S

21 S

12 S

11

+

ASI

+ –

AUX

(24 V

DC

)

(PELV)

1.14

ext. out

ASI

+

0

V

ext. out

ASI

2.14

ext. out

AUX+

ext. in

0

V

ext. out

AUX–

ext. in

S

71 S

72 S

81 S

82

S

42 S

41 S

32 S

31

S

62 S

61 S

52 S

51

S

22 S

21 S

12 S

11

S52

S61

+

ASI

+ –

AUX

(24 V

DC

)

(PELV)

AUX+

ext. in

1.14

ext. out

ASI

+

0

V

ext. out

ASI

2.14

ext. out

AUX+

ext. in

0

V

ext. out

AUX–

ext. in

S

71 S

72 S

81 S

82

S

42 S

41 S

32 S

31

S

62 S

61 S

52 S

51

S

22 S

21 S

12 S

11

S51

S62

I

max

= 10mA

+

ASI

+ –

AUX

(24 V

DC

)

(PELV)

AUX-

ext. in

SPS

PLC

IN

IN

0V

1.14

ext. out

ASI

+

0

V

ext. out

ASI

2.14

ext. out

AUX+

ext. in

0

V

ext. out

AUX–

ext. in

S

71 S

72 S

81 S

82

S

42 S

41 S

32 S

31

S

62 S

61 S

52 S

51

S

22 S

21 S

12 S

11

K2

K1

L1 L2 L3

Motor

AUX+

ext. in

S32

1.14

ext.out

0V

ext.out

+

ASI

+ –

AUX

(24 V

DC

)

(PELV)

ASIMON