11

MeshConnect Overview and Setup

MeshConnect is the wireless control network used with the Handheld Touchscreen for

communication with a Docking Station or Wireless Access Station.

Wireless communications uses Zigbee wireless communication radio (IEEE 802.15.4).

Power for the Handheld unit is provided from the built-in rechargeable battery. You will need

to fully charge the unit before use. Reference

Charging the Handheld Touchscreen, page

37

.

Installation and Configuration Requirements

Prior to connecting your Handheld Touchscreen using MeshConnect, the following

requirements must be met:

All components used including the Handheld Touchscreens, Docking Stations and
Wireless Access Stations must exist in the LightDesigner configuration.

All station Neuron IDs should be added to the LightDesigner configuration.

The LightDesigner configuration should be uploaded to the connected Paradigm
Architectural Control Processor(s).

Docking Stations have been assigned compatible IP Addresses. Reference

page 13

for

instructions to assign the IP Address.

The Docking Station must also be associated by Neuron ID to the configured device in
LightDesigner. The Neuron ID is available from the

Dock (see page 33)

tab in the Setup

menu when a Handheld Touchscreen is docked. It can also be found on the product
label or from the Network view of LightDesigner.

The “Wireless” property of the Handheld Touchscreen station is configured within the
LightDesigner Property Editor for use with the wireless accessory.

The Wireless HF Channel property for all wireless devices must match. By factory
default this setting is HF Channel 10.

To configure the HF Channel property for the Handheld Touchscreen, reference

Select HF Channel, page 23

.

To configure the HF Channel for the Docking Station and Wireless Access Station,
reference the Paradigm Architectural Control Processor Configuration Manual or
reference the LightDesigner online help system.

N o t e :

A Handheld Touchscreen can be associated to multiple Docking Stations and/or

Wireless Access Stations within a configuration. The displayed configuration and

theme may be different for each configured Handheld Touchscreen based on

which Dock or Access station it is connected.

Information related to LightDesigner software including configuration, upload, and

associating Neuron IDs, can be found in the LightDesigner online help system.