beautypg.com

Enerpac ST-202 User Manual

Page 3

background image

4.0 SPECIFICATIONS

4.1 Clamping Force -v- Arm Length Graphs

4.2 PRELIMINARY INFORMATION

IMPORTANT: Failure to read and follow these
instructions may lead to system malfunction or product
failure, and could invalidate your warranty.

1. High flow rates can lead to excessive cylinder

speed which can cause the kick-out mechanism to
activate. Hydraulic pressure and cylinder speed must
be adjusted to match the length of clamp arm. The
clamping force also varies with the length of the clamp
arm.Refer to page 2 for operating specifications.

Refer to page 2 for operating specifications.

2. Flow controls with return checks should be used to

reduce swing cylinder speed to the recommended
rate. The return checks help minimize back pressure
that could lead to an unclamp malfunction on single-
acting systems.

3. When using single-acting swing cylinders, limit the

return flow back pressure to 3,5 bar (50 psi)
maximum. Large diameter tubing (10 mm [3/8 in.]
O.D. or larger) and flow controls with free flow return
checks help minimize back pressure. Consult
Enerpac for proper system design.

4. Excessive return flow back pressure can also

activate the kick-out mechanism on double-acting
swing cylinders. Limit the return flow back pressure
to 42 bar (600 psi) maximum. Double-acting systems
should be set up for a metered-in with reverse free
flow in the clamp port.

5. Clamping of the part should occur at the midpoint of

the vertical travel. No clamping of part shall occur
while the swing clamp is turning. Clamp arm should
freely travel during the 90° rotation (avoid contact
with cutter heads, tools, etc.).

6. Attaching clamp arm to cylinder plunger must be

done according to the instructions on page 6.

(110)

(220)

(340)

(450)

(560)

350

200

160

135

115

100

68

90

110

130

150

165

Pressure bar (psi)

Force kN (lbs.)

CAS-352

CAL-352

Length mm (in.)

4,0 l/min . . . . . . . . . . . . . . . Q . . . . . . . . . . . . . . . . 2,0 l/min

(240 in

3

/min )

(5000)

(2900)

(2320)

(1960)

(1770)

(1450)

0

5

10

15

20

25

(2.68)

(3.55)

(4.33)

(5.12)

(5.90)

(6.50)

35,0 kN (7600 lb) Models

(120 in

3

/min)

(670)

30

(780)

35

(670)

30

(60)

(110)

(170)

(220)

(280)

(340)

350

250

215

175

150

130

120

55

70

90

110

130

150

165

Pressure bar (psi)

Force kN (lbs.)

CAS-202

CAL-202

Length mm (in.)

2,5 l/min . . . . . . . . . . . . . Q . . . . . . . . . . . . . . 1,5 l/min

(150 in

3

/min)

(5000) (3630)

(3120)

(2540)

(2200)

(1890) (1740)

0

2,5

5,0

7,5

10,0

12,5

15,0

(2.17)

(2.76)

(3.55)

(4.33)

(5.12)

(5.90)

(6.50)

18,8 kN (3900 lb) Models

(92 in

3

/min)

(390)

17,5

(450)

20,0

(45)

(90)

(130)

(180)

(220)

(270)

350

265

200

160

135

115

100

45

60

80

100

120

140

160

Pressure bar (psi)

Force kN (lbs.)

CAS-92

CAL-92

Length mm (in.

)

1,0 l/min . . . . . . . . . . . . . Q . . . . . . . . . . . . . . 0,6 l/min

(61 in

3

/min

)

(5000)

(3840)

(2900)

(2320)

(1960)

(1770)

(1450)

0

2

4

6

8

10

12

(1.77)

(2.36)

(3.15)

(3.94)

(4.73)

(5.51)

(6.30)

9,0 kN (2024 lb) Models

(37 in

3

/min )

3

Cylinder Specifications

Capacity kN (lbs)

9,0 kN (2024)

18,8 (3900)

35,0 (7600)

35,0 (7600)

Long Stroke

Body Style

threaded body, lower flange, or upper flange mounting

upper flange

mounting

Cylinder Type

single-acting and double-acting

double-acting

Hydraulic

clamp

12 (0.47)

14,0 (0.55)

16,0 (0.63)

31,8 (1.25)

Stroke [mm (in)]

total

22 (0.87)

28,0 (1.10)

30,0 (1.18)

46,5 (1.83)

Effective Area

clamp

3,13 (0.49)

7,16 (1.11)

12,42 (1.925)

12,42(1.925)

[cm

2

(in

2

)]

unclamp

8,04 (1.25)

15,21 (2.356)

23,76 (3.683)

23,76(3.683)

Oil Capacity

clamp

6,88 (0.42)

20,0 (1.22)

37,2 (2.27)

57,9 (3.53)

[cm

3

(in

3

)]

unclamp

17,69 (1.08)

42,6 (2.60)

71,3 (4.35)

111,0 (6.77)

This manual is related to the following products: