User manual Version 1.1
SE8502-M12 IP68 Serial Server
Copyright © 2010 Atop Technologies, Inc.
All rights reserved
24
Serial Information:
UART mode RS485/RS232/RS422
Link Mode: TCP Server [or TCP Client/UDP Mode, Allows for changes in Serial Page]
Baud rate: 110/150/300/600/1200/2400/4800/9600/19200/38400/57600/115200/230400/460800/921600
Parity: None [or Even/Odd/Space/Mark...Allows for changes in Serial Page]
Data bits: 5, 6, 7, 8 bits
Stop bits 1 bit or 2 bits
Flow Control None, Xon/Xoff, RTS/CTS
4.2. Networking Configuration
Operation: [Main]Æ[2 Networking]:
Select “2” on “Input choice (0~6) and enter:” to enter Networking settings page.
Fig 34. Networking Settings by Telnet
Note: Press “0” key to return to the previous menu
This section allows for changes in IP address, subnet mask, gateway IP address and SNMP information. Please
note that setting changes will not take effect until the SE8502-M12 is restarted.