Atop Technology SW550X Installation Guide User Manual
Hardware installation guide, Atop technologies, inc, Industrial wireless serial device server
Industrial Wireless Serial Device Server
Hardware Installation Guide
Version 1.0
Updated on June, 2012
Technologies
Tel: 886-3-5508137
Fax: 886-3-5508131
www.atop.com.tw
P/N: 89900409G
SW550X Series
Atop Technologies, Inc.
Installation Overview
Field Maintenance and Service
The device’s appearance is as in the figure below.
There are mounting plates and screws that come
inside the package. Proceed to place the screws
on the back of the device as shown in (Fig. 1).
Next we can then proceed to connect the device to the LAN (switch or
PC, depending on the case), take care on using an RJ45
terminal/connector; after this we can then proceed to the device’s
settings.
Other points to take into consideration when installing the device follow next.
The antennas are 3dBi (at 2.4 GHz) and a 5 dBi (at 5GHz); once fixed
to the rail, do not place them parallel, otherwise their signal will
interfere with each other.
Note:
The first two pictures illustrate
not recommended setup for the SW550X;
signal will strongly decrease with the antennas on this position.
Proceed then to fix the antennas to the female
RP-SMA connectors deemed to, (Fig. 3).
You can then choose whether to place the terminal
block at this point or do it later depending on the
actual location of the device or level of comfort for
performing such operation.
(Fig. 3)
(Fig. 2)
1.
2.
5.
3.
Once the plate has been firmly put in place,
proceed to mount the whole device as shown in
(Fig. 4).
Proceed to (Fig. 5) if you want
to remove the device from
DIN-Rail.
4.
■
If the device is not going to be placed on
the rail and to be positioned horizontally,
then the antennas could be setup making
a “V” shape,(Fig. 6).
■
The openings to the sides are for the device’s heat dissipation and
there may be inside hazardous voltages, please never obstruct or
cover them with any objects or try to
insert them through it.
■
SW550X’s factory IP by default is 10.0.50.100 you can access the
device by its Web UI once it is connected to a physical network (or
using Serial Manager, for more information on Serial Manager,
please refer to the manual, Chapter 3). Please be aware that the PC
needed for this procedure needs to be in the same subnet, or you
may refer yourself to the User’s Manual on Sec. 3.1.
If the device requires servicing of any kind, you may need to disconnect
and remove it from its mounting. The initial installation should be done
in a way that makes this as convenient as possible.
■
Voltage/Power lines should be properly insulated as well as other
cables. Be careful when handling them so as to not trip over.
■
Do not under any circumstance insert foreign objects of any kind into
the heat dissipation holes located in the different faces of the device.
This may not only harm the internal layout but might cause harm to
you as well.
■
Do not under any circumstance open the device for any reason.
Please contact your dealer for any repair needed or follow the
instructions on section of your User’s manual.
■
(Fig. 4)
(Fig. 5)
There is a screw close to the power terminal
block this screw is used to connect the grounding
of the SW550X.
Although internal grounding has been done
inside, in order to ensure overall maximum
performance and protect your device it is still
strongly advised to link this point to the ground as
well; hazardous ESD can come into contact with
it and damage your equipment. On the terminal
block, there is a terminal for Frame Ground, you
can choose whether to connect it the grounding,
you may opt between only one of these two
grounds ( the one chosen should be connected at
all times).(Fig. 2)
(Fig. 1)
(Fig. 6)
Package Check List
Pin Assignments
Optional Accessories
Inside the package you will find the following items:
■
Industrial Wireless Serial Device Server SW550X x 1
■
3 ~ 5 dBi antenna x 2
■
3-Pin 5.08mm Lockable Terminal Block x 1
■
5-Pin 5.08mm Lockable Terminal Block x 1
(for SW5501-TB, SW5501-Sis)
■
5-Pin 5.08mm Lockable Terminal Block x 2
(for SW5502-TB, SW5502-Sis)
■
Din Rail Kit x 1 (Already mounted to the device)
■
Installation Guide + Warranty Card x 1
■
CD (User’s Manual / Installation Guide / Serial Manager Utility) x 1
Item
Description
US315-12 (US-Y)
Power Adapter
Y-Type (5.08 mm) power adaptor,
100-240VAC input, 1.25A @ 12VDC output,
US plug
USE315-12 (EU-Y)
Power Adapter
Y-Type (5.08 mm) power adaptor,
100-240VAC input, 1.25A @ 12VDC output,
EU plug
ADP-DB9(F)-TB5
Female DB9 to Female 3.81 TB5 Converter
WMK-454-Black
Black Aluminum Wall Mount Kit
5-pin Terminal Block for RS-422/485
Pin
1
2
3
4
5
RS-422
TXD+
TXD-
RXD+
RXD-
SG
RS-485
N/A
N/A
DATA+
DATA-
SG
1 2 3 4 5
1 2 3 4 5
9-pin D-sub Connector for RS-232/422/485
Pin
1
2
3
4
5
6
7
8
9
RS-232
DCD
RXD
TXD
DTR
SG
DSR
RTS
CTS
RI
RS-485
N/A
N/A
DATA+
N/A
SG
N/A
DATA-
N/A
N/A
RS-422
N/A
TXD+
RXD+
N/A
SG
N/A
RXD-
TXD-
N/A
1 2 3 4 5
6 7 8 9
F.G
V-
V+
ON
SAB
1
2
3
100
80
60
40
20
COM1
COM2
ANT1
ANT2
LAN
Reset
COM1
Status
Tx
Rx
RUN
COM2
WLAN
COM
RUN
ON SAB
1
2
3 4 5
6
F.G
V-
V+
ON
SAB
1
2
3
100
80
60
40
20
COM1
COM2
ANT1
ANT2
LAN
Reset
COM1
Status
Tx
Rx
RUN
COM2
WLAN
COM
RUN
ON SAB
1
2 3 4 5 6
F.G
V-
V+
ON
SAB
1
2
3
100
80
60
40
20
COM1
COM2
ANT1
ANT2
LAN
Reset
COM1
Status
Tx
Rx
RUN
COM2
WLAN
COM
RUN
ON SAB
1
2 3 4
5
6
ON
SAB
12
3
100
80
60
40
20
COM1
COM2
ANT1
ANT2
LAN
Reset
C
O
M
1
Status
T
x
R
x
R
U
N
C
O
M
2
W
LA
N
CO
M
RU
N
ON SAB
1 2 3 4
5 6
ON
SAB
12
3
100
80
60
40
20
COM1
COM2
ANT
1
ANT
2
LA
N
Re
set
C
O
M
1
Status
T
x
R
x
R
U
N
C
O
M
2
W
LA
N
CO
M
RU
N
ON SAB
1 2 3 4 5 6
F.G
V-
V+
ON
SAB
1
2
3
100
80
60
40
20
COM1
COM2
ANT1
ANT2
LAN
Reset
COM1
Status
Tx
Rx
RUN
COM2
WLAN
COM
RUN
ON SAB
1
2 3 4
5
6
F.G
V-
V+
ANT1
ANT2
COM
RUN
ON
SAB
1
2 3
F.G.
V-
V+