Atop Technology SE5001A Installation Guide User Manual
Introduction, Installation overview inside the package, Optional accessories
Introduction
Thank you for choosing the Atop Industrial Serial to Ethernet Serial
Device Server. The SE5001A Series provide industrial grade media
conversion between Ethernet and RS-232/RS-422/RS-485.This Guide
covers two product models:
■
SE5001A
Industrial RS-232/422/485 to Ethernet Serial Device Server, DB9(M)
connector
■
SE5001A-TB
Industrial RS-232/422/485 to Ethernet Serial Device Server, Terminal
Block connector
Installation Overview
Inside the Package
SE5001A
Terminal Block
Installation Guide
Mount Kit
CD (Utilities)
Item
Quantity
Description
Industrial Serial Device Server
Depending on the model you may find:
■ 3-pin 5.08mm lockable terminal block
■ 5-pin 3.81mm lockable terminal block
(SE5001A-TB only)
Hardware Installation Guide for your device
Wall mount kit for the device
Includes:
User’s Manual and Utilities
1
1
1
1
1
Optional Accessories
DK-25
US315-12(US-Y)
USE315-12(EU-Y)
ADP-DB9(F)-TB5
Item
Atop P/N
Description
DIN-Rail Kit
100-240VAC input,
1.25A @ 12VDC output, US plug
100-240VAC input,
1.25A @ 12VDC output, EU plug
Female DB9 to Female 3.81mm TB5
Converter
30200000000022G
50500151120009G
50500151120019G
59906231G
Note:
Please check all the items described above are inside the package; also make
sure your device, items and the package itself present no damages upon
purchase; if not, please notify your sales representative immediately.
Before installing the device in any surface, please read this set of easy
instructions; Atop strongly advices you to follow them as they are a
measure of precaution against accidents, injuries and/or death. If you
are not sure of how to this or in any way feel insecure on the whole
procedure, please refrain from it and call the qualified technician. If still
this is not possible, proceed to contact your sales representative.
■ Be sure there is nothing embedded or concealed under the surface that
we are to drill. Most common cases are concealed electrical wirings and
plumbing.
■ Never ever drill anywhere close to any electrical outlets like sockets,
switches or panels. You can’t be sure where the wires are coming from
but there will be wires running to and from these outlets; the conse
quences for drilling close to them could be serious.
■ In areas close to pipes and/or plumbing, never ever drill close to it; the
consequences for drilling close to them could be serious as well.
Field Maintenance and Service
If the device requires servicing of any kind, you may need to disconnect
and remove it from its mounting. The initial installation should be done in
a way that makes this as convenient as possible.
■ Voltage/Power lines should be properly insulated as well as other
cables. Be careful when handling them so as to not trip over.
■ Do not under any circumstance open the device for any reason.
Please contact your dealer for any repair needed or follow the instruc
tions on section of your User’s manual.
As mentioned before, the SE5001A Series comes with a mounting kit
that consists of 2 screws with their respective wall plugs (i.e., screw
anchors/dowel).
For installing procedures first drill a hole in the surface to be installed
and fill it with the wall plugs. For a set of precautions to take when
drilling holes in walls please read the notes.
Then install the device by fixing it to the surface with the screws as
explained in the figure below.
1.
2.
3.
You can then proceed to plug
in all the cables,
first plug the connectivity
cables(RS-232/RS422/RS485),
and then plug in the power cables
in the terminal block.
SE5001A’s factory IP by default is 10.0.50.100 you can access the
device by its Web UI once it is connected to a physical network (or
using Serial Manager, for more information on Serial Manager,
please refer to the manual). Please be aware that the PC needed for
this procedure needs to be in the same subnet, or you may refer
yourself to the User’s Manual on Sec. 3.1.
4.
5.
Industrial Serial Device Server
Hardware Installation Guide
Version 1.0
Updated on July, 2012
Technologies
Tel: 886-3-5508137
Fax: 886-3-5508131
www.atop.com.tw
P/N: 89900417G
SE5001A Series
Atop Technologies, Inc.
DC 9-48V
COM1
LAN
Reset
SE5001
A
Serial D
evice S
erver
LAN
RUN
Tx
Rx
DC 9-48V
COM1
LAN
RUN
Tx
Rx
LAN
Reset
SE5001A
Serial D
evice S
erver
1 2 3
4 5
LAN RUN Tx
Rx
COM1
SE5001A
DC 9-48V
LAN
Reset
Serial Device Server