User manual Version 1.1
SE8502-M12 IP68 Serial Server
Copyright © 2010 Atop Technologies, Inc.
All rights reserved
11
UDP
In UDP mode, User may exchange Multicast data from one SE8502-M12 with multiple SE8502-M12s, Vice versa is
also true.
Fig 10. UDP Link in Tunneling mode
Configure SE8502-M12 in UDP Mode
Use one of the three configuration methods (Telnet, Web, and console). User can configure SE8502-M12 to UDP
mode. In UDP mode, SE8502-M12 can be configured to communicate to more than one node (Multicasting). Note that
the Multicast IP address is limited by the Class of IP address and subnet mask. As an example, for a network of Class
C of subnet 192.168.1.X and a subnet mask of 255.255.255.0, the maximum Multicast IP address to be configured is
four destinations IP’s.
Fig 11. Multi-UDP Link in Tunneling Mode
3.
Configure SE8502-M12 by web interface
User has to assign IP address to SE8502-M12 before working on web configuration operations. Please refer to
for more detail.
3.1. Login to System
Open one of the web browsers, ex. Microsoft IE or Firefox etc. Enter the IP address of SE8502-M12 on the URL.
Example:
The following authentication screen shall appear. Enter user name and password then click on “OK”. The default
user name is admin and password is null (leave it blank).