Control card -12, Flow control card settings -12, Flow control card ramp time -12 – JLG 460SJ ANSI Service Manual User Manual
Page 278

SECTION 4 - BOOM & PLATFORM
4-12
– JLG Lift –
3120788
the meter for the time it takes the output to go from 0
current to maximum current. This is ramp up time.
Adjust P1 until this time matches the time in table 2.
Rotating the adjustment potentiometer clockwise
will increase ramp time. To set the ramp down time,
hold the telescope function switch and watch the
time it takes the output to go from the maximum cur-
rent down to 0 current. This is the ramp down time.
Adjust P2 until this time matches the setting in table
2. Rotating the adjustment potentiometer clockwise
will increase the ramp time.
NOTE: No ramp needed for drive forward and reverse. THe
drive pump is a slow reacting pump with internally
built in ramp up and down times.
Table 4-2. Flow Control Card Settings
S Models
Function
Minimum Current
Maximum Current
Lift Up
400 mA
1320 mA
Lift Down
500 mA
1500 mA
Swing Right
400 mA
935 mA
Swing Left
400 mA
935 mA
Flow Control
700 mA
1600 mA
Drive Forward (Deutz)
820 mA
1120 mA
Drive Reverse (Deutz)
820 mA
1120 mA
Drive Forward (Ford)
820 mA
1200 mA
Drive Reverse (Ford)
820 mA
1200 mA
Figure 4-9. Control Card
Table 4-3. Flow Control Card Ramp Time
Function
Ramp Time
Lift Up
Ramp Up Time = 2:00 sec.
Ramp Down Time = 2:00 sec.
Lift Down
Ramp Up Time = 3:00 sec.
Ramp Down Time = 2:00 sec.
Swing Right
Ramp Up Time = 3:50 sec.
Ramp Down Time = 2:00 sec.
Swing Left
Ramp Up Time = 3:50 sec.
Ramp Down Time = 2:00 sec.
Drive Forward
Ramp Up Time = none
Ramp Down Time =none
Drive Reverse
Ramp Up Time =none
Ramp Down Time = none
Flow Control
(Tele, Rotate, Jib)
Ramp Up Time = 3:00 sec.
Ramp Down Time = 0:00 sec.