As-interface single slave output addressing – Norgren VS18 Series Valve Advantage User Manual
Page 78
VS18/VS26
MAINTENANCE & INSTRUCTION BOOKLET
8.6.4 AS-Interface
single slave valve island configurations and settings
The VS18/VS26 AS-Interface single slave valve island can have two to four valve stations with
a maximum of four outputs. To change the configuration, operate the DIP switches accessible
by removing the securing screw and lifting the hinged cover.
Single slave
DIP switch
Mode
1
2
2 valves
2 x sol/sol
1 1
3 valves
1 x sol/sol &
2 x sol/spring
1 0
4 valves
4 x sol/spring
0 0
Configuration switch:
O
N
1
2
1 0
8.6.5 AS-Interface
single slave output addressing
Allocation of data bytes and data bits to solenoids
Data byte.Data bit (eg. byte 0 / bit 3
0.3)
No of valves
ª
Valve no.
¨
1
2
3
4
Solenoid 14
0.0
0.1
2 valves
Solenoid 12
0.3
0.2
Solenoid 14
0.0
0.1
0.2
3 valves
Solenoid 12
0.3
Solenoid
14
0.0 0.1 0.2 0.3
4 valves
Solenoid 12
Solenoids 12
Valve no.
Solenoids 14
VS2672926-KG00E_05/07 Page
78/97