Norgren 33D Electronic Pressure Switches Datasheets User Manual
Psc- 6, Herion 33d series, Options selector
www.norgren.com/info/US-PSC-6
PSC-
6
P
R
E
S
S
U
R
E
S
E
N
S
IN
G
A
N
D
C
O
N
T
R
O
L
Technical data
Medium
Pneumatic types: compressed air or
neutral gases
All fluid types: gasses or liquids,
including aggressive
Display
LCD 4 digits illuminated, pressure unit
programmable for bar, psi, mpa
Mounting position
Optional
Operating pressure
Vac to 230 psi (pneumatic)
0 to 9100 psi (hydraulic/allfluid)
Temperature sensitivity
(zero point)
0.4% of final value/10 K
Temperature sensitivity
(range)
0.4% FS/10 K
Ambient temperature
14°F to 140°F (-10°C to 60°C)
Fluid temperature
14°F to 75°F (-10°C to 80°C)
Switching point
Adjustable between 0 and 100% FS
Reset point
Adjustable between 0 and 100% FS
Electrical connection
M12 x 1
Linearity
< 0.2% FS ±1 digit
Degree of protection to DIN
40 050
IP 65 (with mounted plug)
Materials
Housing: aluminum
Pneumatic version
Seal : viton O-ring (FKM)
Sensor: silicon
Hydraulic/All fluid version
Porting block / sensor: 316 SS welded
Herion 33D Series
Solid state switches (pneumatic / all-fluid)
Vac to 9100 psi
Model number - standard pneumatic models*
* M12 x 1 connector not included. Please see table on next page.
** 4-20 mA option not available on flange mounted versions.
Options selector
0863
˙ ˙ ˙
Pressure range (pneumatic)
Substitute
Vac–15 psi
0
0 – 230 psi
2
Fluid/electrical connection
Substitute
GÊ, M12 x 1
2
Ê NPT, M12 x 1
4
Flange, M12 x 1
6
Output signal
Substitute
1 digital out
1
2 digital out
2
1 digital out/4 – 20 mA**
4
Pressure range (allfluid)
Substitute
0 – 145 psi
1
0 – 580 psi
3
0 – 1450 psi
4
0 – 2300 psi
5
0 – 3600 psi
6
0 – 5800 psi
7
0 – 9100 psi
8
Port
Measuring range (psi)
Maximum overpressure
Output
Model
size
(relative pressure)
(psi)
signal
1/4 NPT
Vac–15
145
1 x PNP
0863014
Flange
Vac–15
145
1 x PNP
0863016
1/4 NPT
Vac–15
145
2 x PNP
0863024
Flange
Vac–15
145
2 x PNP
0863026
1/4 NPT
Vac–15
145
1 x PNP / 4–20 mA
0863044
Flange
Vac–15
145
1 x PNP / 4–20 mA
0863046
1/4 NPT
0 – 230
435
1 x PNP
0863214
Flange
0 – 230
435
1 x PNP
0863216
1/4 NPT
0 – 230
435
2 x PNP
0863224
Flange
0 – 230
435
2 x PNP
0863226
1/4 NPT
0 – 230
435
1 x PNP / 4–20 mA
0863244
Flange
0 – 230
435
1 x PNP / 4–20 mA
0863246
Real time pressure display with
backlight
Compact and robust design
Easy programming of set points
and additional functions
Transistor output signals 1 x PNP,
2 x PNP, or 1 x PNP + 4 to 20 mA
Electronic lock
Switching status indicated by LED
Standard M12x1 electrical
connection (IP 65)
For pneumatic, all fluid and
hydraulic applications