Electrical, Voltage tolerances, Required performance of power supply unit – Norgren VS18 Series Valve Advantage User Manual

Page 12: Power supply and precautions, Lectrical, For information on power supply and earth

background image

VS18/VS26

MAINTENANCE & INSTRUCTION BOOKLET

4.4 E

LECTRICAL

4.4.1 Voltage

tolerances

Voltage

Voltage tolerances

24V DC

+/-10%

115V AC

-10%/+15%


4.4.2 Required performance of power supply unit

The required performance can be calculated from the maximum number of energized solenoids
at the same time. In case of a Fieldbus valve island the consumption of power of the electronic
has to be considered (see section

8

).


4.4.3 Power supply and precautions

All VS18/VS26 24V DC products are designed to be used with a protective extra low voltage
(PELV) power supply (UL Class 2 Supply only).

All VS18/VS26 115V AC products correspond to the protection class I. Connection of the
protective earth (PE) ground is required.