Pneumatic, Response times vs valves, Neumatic – Norgren VS18 Series Valve Advantage User Manual
Page 10
VS18/VS26
MAINTENANCE & INSTRUCTION BOOKLET
4.3 P
NEUMATIC
4.3.1 Response times VS valves
The response measurements are taken according to ISO 12238 standard.
Glandless valves VS**G
VS18
VS26
Response
time ON (ms)
Response
time OFF (ms)
Response
time ON (ms)
Response
time OFF (ms)
5/2
Sol/Spring
18 54 24 58
5/2
Sol/Sol
18 18 20 20
5/2 Sol (priority side 14)/Sol
14
1)
21
2)
14
1)
21
2)
5/3 APB Sol/Sol
24
37
26
52
5/3 COE Sol/Sol
25
49
28
52
Softseal valves VS**S
VS18
VS26
Response
time ON (ms)
Response
time OFF (ms)
Response
time ON (ms)
Response
time OFF (ms)
2x2/2 NC Sol/Sol
24
21
29
29
2x2/2 NO Sol/Sol
24
21
29
29
2x2/2 NO/NC Sol/Sol
24
21
29
29
2x3/2 NC Sol/Sol
20
22
32
25
2x3/2 NO Sol/Sol
20
22
32
25
2x3/2 NO/NC Sol/Sol
20
22
32
25
5/2
Sol/Spring
16 42 18 46
5/2
Sol/Sol
14 14 14 14
5/3 APB Sol/Sol
18
40
20
55
5/3 COE Sol/Sol
18
40
19
55
1)
ON side 14
2)
ON side 12
APB = All ports blocked
COE = Centre open exhaust
NC = Normally closed
NO = Normally open
VS2672926-KG00E_05/07 Page
10/97