beautypg.com

As-interface, As-interface pin assignment, As-i – Norgren VS18 Series Valve Advantage User Manual

Page 76: Nterface, As-interface section, 6 as-i

background image

VS18/VS26

MAINTENANCE & INSTRUCTION BOOKLET

8.6 AS-I

NTERFACE

Norgren AS-Interface Fieldbus systems conform to AS-I V2.11
specification.

Communication system:

2-wire ASi bus
communication, electronic
and input power

Number of nodes per network:

Master + 31 slaves (62 slaves for V2.1-slaves which do
not use four outputs). The VS18/VS26 ASi valve islands
always has four outputs.

Total number of I/O per network:

248

Bus topology:

Tree


Note:

The valve island must be mounted on an earthed base to meet the EMC directives.

8.6.1 AS-Interface pin assignment

M12 4-pin bus connector (IP65)

Male

Pin no.

Function

Max. current

1 AS-I

+

3)

2 -

-

3 AS-I

-

4 -

-

Looking into node connector





M12 4-pin power connector for AS-Interface (IP65)

Male

Pin no.

Function

Tolerance

Max. current

1 +24V

DC

+/-10%

4)

2 -

- -

3 0V

- -

4 -

- -

Looking into node connector

3)

Single slave: 40mA

Double

slave:

75mA

4)

Single slave: I

max

= 20mA + n*60mA

Double

slave:

I

max

= 35mA + n*60mA

n = number of energized solenoids

VS2672926-KG00E_05/07 Page

76/97

This manual is related to the following products: