Norgren C002 Series User Manual
Technical data, standard models with silencer, Technical features c˙0˙˙˙ option selector
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. © 2014 Norgren America
N/en 5.3.600.01
CR04 and C002 series
3/2 Inline lockout valves
G1/2 . . . G1; 1/2 PTF ... 1 PTF
7/14
2014-5343b
Technical data, standard models with silencer
High flow
Easily identification
Manually operated with detent
Helps you comply to OSHA regulations,
as they relate to OSHA regulation 29 CFR Part
1910, standard for lockout/tagout
procedures
Symbol
Basic size Port size
Flow
1 » 2 2 » 3
(l/min) (l/min)
Handle
colour
Weight
(kg)
Model
2
1
3
1/2”
G1/2
8200
6970
Red
0,95
CR043C
1/2 PTF
8200
6970
Black
0,96
C0023C
G3/4
11120
7590
Red
0,92
CR043D
3/4 PTF
11120
7590
Black
0,93
C0023D
1”
G1
14300
8120
Red
1,88
CR044B
1 PTF
14300
8120
Black
1,89
C0024B
Medium:
Compressed air
Maximum pressure:
20 bar
Flow:
See table below
Port size:
G1/2, G3/4 or G1
1/2 PTF, 3/4 PTF or PTF
Ambient/Media temperature:
-30 ... +80°C
Air supply must be dry enough
to avoid ice formation at
temperatures below +2°C .
Materials:
Valve body: Aluminum
Silencer base: Zinc
Spool, T-Handle, silencer shell:
Aluminum
Spring detent: Stainless steel
Elastomers: NBR and PUR
Technical features
C˙0˙˙˙
Option selector
Handle colour
Substitute
Red
R
Black
0
Thread form
Substitute
PTF
2
ISO G
4
Base size
Substitute
1/2”
3
1”
4
Port size
Substitute
1/2” ( 1/2” base size)
C
3/4” (1/2” base size)
D
1” (1” base size)
B