Pneumatic high-speed pressure controller cpc3000 – WIKA CPC3000 User Manual
Page 53

Pneumatic High-Speed Pressure Controller CPC3000
WIKA Operating Instruction Pneumatic High-Speed Pressure Controller ∙ Version 1.1
53
11498171.01 08/2009 GB
Command
Data
Response/Function
*ESE?
Returns enable status event value
*ESR
Event status register
*ESR?
Returns event status register value
*SRE
Service request enable
*SRE?
Returns service request enable value
*STB?
Returns status byte
8.5.6 SCPI Commands
Notes:
1. if Wika option is enabled, SCPI units are BAR, otherwise SCPI units are the currently select-
ed unit.
This numeric suffix always defaults to 1 and is designated by [R] (range)
Command
Response/Function
MEASure
[:PRESsure][R]?
Returns the pressure from sensor R
:TEMPerature[R]?
Returns the temperature from sensor R
:RATE[R]?
Returns the rate/sec from sensor R
:BAROmetric?
Returns the barometric pressure
CALibration
[:PRESsure][R]
:MODE?
Returns 1=calibrated or 0=not calibrated
:DATE?
Returns date of cal “DD,MM,YY”
:DATE
Sets date of cal YYYY,MM,DD
:ZERO?
Returns zero offset
:ZERO
Sets the zero offset
:ZERO:RUN
Same as CAL:ZERO 0
:ZERO:INITiate?
Returns zero status
:ZERO:INITiate
No function
SENSe
[:PRESsure][R]
:NAME?
Returns sensor name string
:MODE?
Returns “ABSOLUTE” or “GAUGE”
:MODE ABS|GAUGE
Sets pressure type
:ABS?
Returns native sensor type 0=GAUGE
1=ABSOLUTE
:RESolution?
Returns resolution (float)
:RANGe
[:UPPer]?
Returns maximum range
:LOWer?
Returns minimum range