Configuring the Number of Installed Input and Output Ports

31

31

8.2.8 Config Menu—Display Firmware Versions

This option displays the main and front firmware versions.
To display the firmware versions:

1. Press MENU twice.

The following message is displayed:

start configuration menu

MENU to view setup ENT to change them

2. Press MENU until the following is displayed:

Main Firmware Version:

1.0

Front Firmware Version:

1.0

3. Either:

Press BREAKAWAY to exit the Config Menu

Wait approximately 15 seconds for the operation to time out

9 Configuring the Number of Installed Input and Output

Ports

After installing or removing a module you need to set the number of input

and output ports so that the VS-6464DN recognizes the new configuration.

Refer to

Section 6.1

for an explanation of port numbering before setting the

number of input and output ports.
To set the number of input or output ports:

1. Press ESC, ENT and LOCK together.

The following is displayed:

Configuration Device

2. Press ENT.

The following is displayed:

Test Board: 0 MaxInput:64 MaxOutput:64

Note: The number of input and output ports can only be set in units of eight,

for example, 8 x 8, 64 x 8 or 40 x 16, and not 5 x 4 or 12 x 17.
3. Using the numeric keys, enter the number of input and output ports

installed.

The TAKE button flashes.

4. Press TAKE.

The number of installed ports is saved and the display reverts to the

output/input display.

5. Reboot the device by turning the power off and then on again.