Using the Configuration Menu
23
23
8.1.1 Setup Menu—1: inXX=>ALL, Switching one Input to all Outputs
This option switches one input to all outputs.
To switch one input to all outputs:
1. Press MENU.
The Setup Menu options are displayed.
2. Press 1 (ALL) on the numeric keypad (see
).
The following is displayed:
in__ => ALL
3. Using the numeric keys, enter the input to be switched to all outputs.
The TAKE button flashes.
4. Press TAKE.
The selected input is switched to all outputs.
The display reverts to the output/input display showing that the
selected input is switched to all outputs.
8.1.2 Setup Menu—3: outXX=>OFF, Turning an Output Off
This option turns an output off.
To turn an output off:
1. Press MENU.
The Setup Menu options are displayed.
2. Press 3 (OFF) on the numeric keypad (see
).
The following is displayed:
out__ => OFF
3. Using the numeric keys, enter the output to be turned off.
The TAKE button flashes.
4. Press TAKE.
The selected output is turned off.
The display reverts to the output/input display showing that the
selected output is turned off with the input being blank.
8.1.3 Setup Menu—7: EDID, Assignment to an Input
This option assigns an EDID to between one and eight inputs at a time
which are stored in non-volatile memory. More than eight EDID
assignments must be assigned in separate batches of eight.
Each input on the VS-6464DN has a factory default EDID loaded (see
Section 16
). The EDID for each input can be changed independently via the
menu (described below) or by uploading an EDID binary file to each input
via the RS-232 port using Kramer EDID Designer software