5 config menu—protocol configuration, 6 config menu—store default setup, Config menu—protocol configuration – Kramer Electronics VS-6464DN User Manual
Page 33: Config menu—store default setup

Using the Configuration Menu
29
29
To switch the Reply configuration on or off:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENT to change them
2. Press MENU until the following is displayed:
interface REPLY configuration
current interface REPLY -- ON
This indicates the current Reply configuration status.
3. Press ENT to enter the Reply Submenu.
The following is displayed:
interface REPLY configuration
1:turn REPLY ON
2:never REPLY
4. Press 1 to switch Reply on or 2 to switch it off.
5. Press TAKE to confirm the action.
A message is displayed indicating the new status of the Reply
configuration. After a few seconds the next option on the Config Menu
is displayed.
8.2.5 Config Menu—Protocol Configuration
The VS-6464DN supports Kramer Protocol 2000. There are currently no
options to modify.
8.2.6 Config Menu—Store Default Setup
This option lets you store the current setup as the default setup. The default
setup can be recalled at any time using the DEFAULT SETUP button (see
Section 7.4.5
).
Note: This is not the setup that is loaded when the unit is switched on.
To store the current setup as the default setup:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENT to change them
2. Press MENU until the following is displayed:
store DEFAULT setup
press ENTER to store
3. Press ENT to store the current configuration as the default
configuration.
The following is displayed:
current matrix stage is OKAY?
press TAKE to confirm