3 config menu—interface configuration, 4 config menu—interface reply configuration, Config menu—interface configuration – Kramer Electronics VS-6464DN User Manual
Page 32: Config menu—interface reply configuration, N 8.2.3

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Using the Configuration Menu
28
2. Press MENU until the following is displayed:
OUT: 01 02 03 04 05 06 07 08 09 10 11
LOAD: Y X Y Y Y Y X Y Y Y X
•
Y indicates that a load is attached and X indicates that no load is
detected on the relevant output.
3. Do one of the following:
Press BREAKAWAY to exit the Config Menu
Wait approximately 15 seconds for the operation to time out
Press MENU to move to the next Config Menu option
8.2.3 Config Menu—Interface Configuration
This option lets you activate or deactivate the IR (infrared) and Ethernet
interfaces.
To activate or deactivate the IR or Ethernet interfaces:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENT to change them
2. Press MENU until the following is displayed:
INTERFACE configuration
current:IR-ON Ethernet-ON
The current status of the IR and Ethernet interfaces is displayed.
3. Press ENT to select the Interface Submenu.
4. Select 1 to modify the status of the IR interface or 2 to modify that
status of the Ethernet interface (in this example, 2).
The following is displayed:
Ethernet interface setup
1:make it ACTIVE
2:turn it OFF
5. Press 1 to activate the interface or 2 to deactivate it.
6. Press TAKE to confirm the action.
The interface status is changed. After a few seconds the next option on
the Config Menu is displayed.
8.2.4 Config Menu—Interface Reply Configuration
This option lets you switch the Reply configuration on or off. Setting Reply
to on causes all interfaces that are set to on to accept and execute
commands, and also to reply. Setting Reply to off causes all interfaces that