background image

4.3.2 Bus configuration without CMD software

Logical addressing

One or several configuration lists have been created in
the SPC or in the INTERBUS module for logical
addressing. These lists contain at least the following
entries:

– the ID codes of all the slaves

– the logical addresses of all the slaves

– the number of inputs

– the number of outputs

These specifications must be known or ascertained for
every slave. To do this proceed as follows with the
SPC200:

Assign the ID code 3

D

to each SPC200.

Assign a logical number to each SPC200.

Assign a logical IN and OUT address to each
SPC200. Depending on the operating mode of the
SPC200 and on the I/O configuration set with
WinPISA, the field bus module of the SPC200 oc-
cupies the appropriate number of bits (inputs/outputs,
see Chapters 4.2.2 and 4.1.3).