I/o control signals (summary) – Festo Кабели и принадлежности User Manual
Page 40
I/O control signals (summary)
Detailed explanations of the I/O control signals can be
found in the manual for the SPC200. A detailed sum-
mary of the I/O assignment is shown in section 4.4.2.
Start/stop mode
Address *)
Control signal
Description
I10.0
ENABLE
Enable controller (1=controller enabled)
I10.1
START/RESET
Start/continue programs or
reset (RESET in conjunction with STOP=0)
I10.2
STOP
Stop program run (0=stopped)
I10.3/I10.4
SYNC_A/B
Synchronization input for M00
Q10.0
READY
System ready
Q10.1/Q10.2
SYNC_OA/B
Synchronization output for M00
Q10.3/Q10.4
MC_A/B
MC output for program A/B (motion complete)
*) Address specifications as seen by SPC200
Record select mode
Address *)
Control signal
Description
I10.0
ENABLE
Enable controller
I10.1
RESET
Reset programs
(in conjunction with STOP=0)
I10.2
STOP
Stop positioning task (0=stopped)
I10.3/I10.4
CLK_A/B
Start NC record from program A/B
I11.0 ... I11.15
RECBIT1...10
Bits for NC record number (RECBIT1 for 2
0
etc.)
Q10.0
READY
System ready
Q10.1/Q10.2
ACK_A/B
Task accepted for program A/B
Q10.3/Q10.4
RC_A/B
NC record concluded by program A/B
*) Address specifications as seen by SPC200
4. Commissioning
4-6
SPC200-COM-IBS 0503a